{"id":81004,"date":"2026-11-11T19:02:16","date_gmt":"2026-11-11T11:02:16","guid":{"rendered":"https:\/\/www.scondar.com\/?p=81004"},"modified":"2026-11-19T13:18:49","modified_gmt":"2026-11-19T05:18:49","slug":"pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals","status":"publish","type":"post","link":"https:\/\/www.scondar.com\/ru\/2026\/11\/11\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\/","title":{"rendered":"POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals"},"content":{"rendered":"<h1>POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals<\/h1>\n<p>It is Saturday morning. The checkout line is six people deep. The POS terminal at register three is down\u2014cash drawer will not open. The technician is on site, but the problem is not the cash drawer mechanism itself; it is the connector on the cash drawer harness that failed after 30,000 open-close cycles. This is a preventable failure. The connector was specified correctly at design-in; it was just never validated for the actual cycle count the product would see in the field.<\/p>\n<h2>The POS connector selection problem: cycle counts and thermal budgets<\/h2>\n<p>Every sub-system in a POS terminal has a different connector problem. The thermal print head runs hot and cycles rapidly. The cash drawer cycles mechanically with every transaction. The power input runs continuously, 16+ hours a day. The display module sits in the smallest footprint on the board. Solving for one constraint usually creates a problem for another\u2014unless each sub-system is specified independently.<\/p>\n<h2>Sub-system-by sub-system connector matching<\/h2>\n<h3>Thermal print head power (SCT2516)<\/h3>\n<p>The POS machine connector for the thermal print head and the POS machine connector for the cash drawer are different specifications serving different constraints. The print head runs hot and demands thermal margin; the cash drawer cycles mechanically and demands cycle-rated retention. A single POS machine connector type cannot optimally serve both interfaces\u2014which is why the mixed-strategy approach (SCT2516 for print head, SCT2020 for cash drawer) is the standard in well-designed POS terminal wire harness specifications.<\/p>\n<p>The POS machine connector serving the cash drawer interface is selected by cycle count, not current rating\u2014a connector rated for continuous power is not rated for the repeated mechanical cycling of a cash drawer.<\/p>\n<p>A POS machine connector is not a single specification\u2014it is a set of interface decisions, each matched to a different sub-system requirement inside the POS terminal.<\/p>\n<p>The print head is the most thermally demanding sub-system in a POS terminal. It cycles rapidly, runs hot during long print jobs, and draws current pulses during actuation. The connector must handle 3\u20135A running current with 60%+ margin for thermal head inrush, operate at +105\u00b0C without degradation, and lock positively enough to survive the vibration of paper feed mechanisms. The SCT2516 ( Mini-Lock compatible, 2.5mm pitch, 5A, four-point contact) is the match for this sub-system. The four-point contact design is the key differentiator: it maintains electrical continuity even if one or two contact points are affected by vibration-induced micro-movement.<\/p>\n<p>Each POS machine connector in the terminal is specified for a different constraint: thermal stress at the print head, mechanical cycling at the cash drawer, and board space at the display. Treating them as one connector type is the root cause of most POS terminal field failures.<\/p>\n<p>For the POS machine connector serving the thermal print head, the SCT2516 four-point contact design maintains electrical continuity under the vibration and thermal stress of a POS machine connector in a high-volume retail environment.<\/p>\n<p>For POS machine connector thermal derating in high-volume production environments, verify the actual print head zone temperature against the SCT2516\u2019s \u221240\u00b0C to +105\u00b0C rating before committing to production.<\/p>\n<p>Browse the full range of SCONDAR<a href=\"https:\/\/www.scondar.com\/wire-to-board\/\">wire-to-board connectors for POS and retail equipment<\/a>\u2014all pitch ranges and current classes.<\/p>\n<h3>Power input header (SCT2541)<\/h3>\n<p>For the cash drawer interface, the POS machine connector must handle repeated mechanical cycling\u2014not just electrical current. The SCT2020 dual-lock mechanism is the POS machine connector designed for this high-cycle mechanical interface.<\/p>\n<p>The power input header is a continuous-duty connector: 16+ hours per day, 365 days a year. The SCT2541 ( KK 254 compatible, 2.54mm pitch, 3A) delivers friction-lock reliability at the power rail with UL94V-0 rated PA66 housing\u2014essential for fire safety compliance in commercial equipment. The double-cantilever contact design maintains consistent contact force over the full service life of the terminal.<\/p>\n<p>The POS machine connector for the power input rail operates 16+ hours per day, 365 days a year\u2014the SCT2541 with UL94V-0 rated housing is the appropriate POS machine connector for this always-on power interface in a commercial retail environment.<\/p>\n<h3>Display module FFC\/FPC connections (SCT1258)<\/h3>\n<p>Working on a POS machine connector specification and need a second opinion? Describe the sub-system, the failure mode, and the cycle count in the comments. Our team follows up on POS machine connector inquiries with specific recommendations.<\/p>\n<p>TFT display modules in POS terminals sit in the smallest-footprint area of the board. The SCT1258 (1.25mm pitch, JST GH compatible) handles flat cable (FFC\/FPC) connections here with its large outer latch for tactile mating confirmation. The compact pitch saves board space; the audible latch confirms correct seating on high-volume assembly lines.<\/p>\n<h3>Cash drawer and high-cycle peripheral interfaces (SCT2020)<\/h3>\n<p>The scenario at the start of this article: a cash drawer that fails after 30,000 cycles. The root cause is usually a connector specified for static power connections but used for a high-cycle mechanical interface. The SCT2020 (JST PUD compatible, 2.0mm pitch, 3A) is designed for this: its dual-lock anti-pullout mechanism handles the repeated open-close stress that defeats standard friction-lock connectors. Specifying the right connector for this interface is a low-cost decision that prevents exactly the Saturday-morning service call described above.<\/p>\n<h2>Technical Specifications<\/h2>\n<table>\n<tr>\n<th>Series<\/th>\n<th>Ref<\/th>\n<th>Pitch<\/th>\n<th>Current<\/th>\n<th>Voltage<\/th>\n<th>Temp<\/th>\n<th>Best For<\/th>\n<\/tr>\n<tr>\n<td>SCT2516<\/td>\n<td>Mini-Lock<\/td>\n<td>2.5 mm<\/td>\n<td>5A<\/td>\n<td>250V<\/td>\n<td>\u221240\u00b0C~\u2212105\u00b0C<\/td>\n<td>Print head power; vibration resistance<\/td>\n<\/tr>\n<tr>\n<td>SCT2541<\/td>\n<td>KK 254<\/td>\n<td>2.54 mm<\/td>\n<td>3A<\/td>\n<td>250V<\/td>\n<td>\u221225\u00b0C~\u221285\u00b0C<\/td>\n<td>Power input; fire safety rated<\/td>\n<\/tr>\n<tr>\n<td>SCT2023<\/td>\n<td>CLIK-Mate<\/td>\n<td>2.0 mm<\/td>\n<td>3A<\/td>\n<td>250V<\/td>\n<td>\u221240\u00b0C~\u2212105\u00b0C<\/td>\n<td>Stepper motor; vibration-resistant<\/td>\n<\/tr>\n<tr>\n<td>SCT2020<\/td>\n<td>JST PUD<\/td>\n<td>2.0 mm<\/td>\n<td>3A<\/td>\n<td>250V<\/td>\n<td>\u221225\u00b0C~\u221285\u00b0C<\/td>\n<td>Cash drawer; dual-lock anti-pullout<\/td>\n<\/tr>\n<tr>\n<td>SCT1258<\/td>\n<td>JST GH<\/td>\n<td>1.25 mm<\/td>\n<td>1A<\/td>\n<td>50V<\/td>\n<td>\u221225\u00b0C~\u221285\u00b0C<\/td>\n<td>Display FFC\/FPC; compact signal<\/td>\n<\/tr>\n<\/table>\n<h2>Design-In Considerations<\/h2>\n<h3>Cycle count vs connector type: a common mis-specification<\/h3>\n<p>The SCT2541 friction-lock is fine for the power input (mated once, stays mated). It is not fine for the cash drawer interface. If your thermal analysis shows the print head zone exceeds 85\u00b0C, check whether the SCT2516\u2019s \u221240\u00b0C to +105\u00b0C rating has adequate margin at your peak ambient. Derating the current by 20% in high-ambient conditions is standard practice for thermal print head circuits.<\/p>\n<h2>Quality Assurance &amp; Supply Chain<\/h2>\n<ul>\n<li>ISO 9001:2015 quality management (Certificate No. 02816Q11592RS); automated production at Dongguan facility<\/li>\n<\/ul>\n<ul>\n<li>RoHS and REACH compliant; UL94V-0 rated housings for fire safety compliance<\/li>\n<\/ul>\n<ul>\n<li>Free sample kits for design validation; 2\u20134 week lead times<\/li>\n<\/ul>\n<ul>\n<li>Delivered interconnect solutions to over 2,000+ global electronics and industrial equipment manufacturers since 2008<\/li>\n<\/ul>\n<h2>Frequently Asked Questions<\/h2>\n<h3>We are seeing cash drawer connector failures in the field after 12\u201318 months\u2014what are we doing wrong?<\/h3>\n<p>Likely two issues: the connector is a friction-lock type specified for static power connections, and it has not been validated against the actual cycle count. A cash drawer in a busy retail environment can see 50\u2013100+ open-close cycles per day\u2014that is 20,000\u201340,000 cycles per year. The fix is the SCT2020 (JST PUD compatible, dual-lock anti-pullout), which is designed for high-cycle peripheral interfaces. Validate pull-out force on production samples before committing to production, and specify the connector based on cycle count, not just current rating.<\/p>\n<h3>Can we use the same connector series for both the thermal print head and the power input in a compact POS terminal?<\/h3>\n<p>Not recommended. The print head runs at elevated temperatures (\u226480\u00b0C at the print head zone) and draws pulsed currents up to 3\u00d7 running current during actuation. The power input runs at room temperature and continuous current. The SCT2516 (\u221240\u00b0C to +105\u00b0C, 5A) handles the print head. The SCT2541 (\u221225\u00b0C to +85\u00b0C, 3A) handles the power rail. Mixing them by sub-system is the right approach\u2014the cost premium of the right connector per interface is minimal compared to a field failure or warranty claim.<\/p>\n<p>Dealing with connector failures in a POS terminal platform? Note the sub-system, the cycle count or thermal environment, and the failure mode in the comments. Our technical team can suggest a connector re-specification or validate the current selection against your actual field conditions.<\/p>\n<p>Free sample kits for re-qualification are available\u2014<a href=\"https:\/\/www.scondar.com\/contact\/\">request yours here.<\/a><\/p>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"We are seeing cash drawer connector failures in the field after 12\u201318 months\u2014what are we doing wrong?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Likely two issues: the connector is a friction-lock type specified for static power connections, and it has not been validated against the actual cycle count. A cash drawer in a busy retail environment can see 50\u2013100+ open-close cycles per day\u2014that is 20,000\u201340,000 cycles per year. The fix is the SCT2020 (JST PUD compatible, dual-lock anti-pullout), which is designed for high-cycle peripheral interfaces. Validate pull-out force on production samples before committing to production, and specify the connector based on cycle count, not just current rating.\"}}, {\"@type\": \"Question\", \"name\": \"Can we use the same connector series for both the thermal print head and the power input in a compact POS terminal?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Not recommended. The print head runs at elevated temperatures (\u226480\u00b0C at the print head zone) and draws pulsed currents up to 3\u00d7 running current during actuation. The power input runs at room temperature and continuous current. The SCT2516 (\u221240\u00b0C to +105\u00b0C, 5A) handles the print head. The SCT2541 (\u221225\u00b0C to +85\u00b0C, 3A) handles the power rail. Mixing them by sub-system is the right approach\u2014the cost premium of the right connector per interface is minimal compared to a field failure or warranty claim.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals It is Saturday morning. The checkout line is six people deep. The POS terminal at register three is down\u2014cash drawer will not open. The technician is on site, but the problem is not the cash drawer mechanism itself; it is the connector on the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-81004","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals - SCONDAR<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.scondar.com\/ru\/2026\/11\/11\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals - SCONDAR\" \/>\n<meta property=\"og:description\" content=\"POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals It is Saturday morning. The checkout line is six people deep. The POS terminal at register three is down\u2014cash drawer will not open. The technician is on site, but the problem is not the cash drawer mechanism itself; it is the connector on the [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.scondar.com\/ru\/2026\/11\/11\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\/\" \/>\n<meta property=\"og:site_name\" content=\"SCONDAR\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-11T11:02:16+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-19T05:18:49+00:00\" \/>\n<meta name=\"author\" content=\"info@scondar.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c\" \/>\n\t<meta name=\"twitter:data1\" content=\"info@scondar.com\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/11\\\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/11\\\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\\\/\"},\"author\":{\"name\":\"info@scondar.com\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\"},\"headline\":\"POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals\",\"datePublished\":\"2026-11-11T11:02:16+00:00\",\"dateModified\":\"2026-11-19T05:18:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/11\\\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\\\/\"},\"wordCount\":1320,\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"ru-RU\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/11\\\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\\\/\",\"url\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/11\\\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\\\/\",\"name\":\"POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals - SCONDAR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#website\"},\"datePublished\":\"2026-11-11T11:02:16+00:00\",\"dateModified\":\"2026-11-19T05:18:49+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/11\\\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/11\\\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/11\\\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.scondar.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#website\",\"url\":\"https:\\\/\\\/www.scondar.com\\\/\",\"name\":\"SCONDAR\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.scondar.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\",\"name\":\"info@scondar.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"caption\":\"info@scondar.com\"},\"sameAs\":[\"https:\\\/\\\/www.scondar.com\"],\"url\":\"https:\\\/\\\/www.scondar.com\\\/ru\\\/author\\\/scondar-2\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals - SCONDAR","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.scondar.com\/ru\/2026\/11\/11\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\/","og_locale":"ru_RU","og_type":"article","og_title":"POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals - SCONDAR","og_description":"POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals It is Saturday morning. The checkout line is six people deep. The POS terminal at register three is down\u2014cash drawer will not open. The technician is on site, but the problem is not the cash drawer mechanism itself; it is the connector on the [&hellip;]","og_url":"https:\/\/www.scondar.com\/ru\/2026\/11\/11\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\/","og_site_name":"SCONDAR","article_published_time":"2026-11-11T11:02:16+00:00","article_modified_time":"2026-11-19T05:18:49+00:00","author":"info@scondar.com","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c":"info@scondar.com"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.scondar.com\/2026\/11\/11\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\/#article","isPartOf":{"@id":"https:\/\/www.scondar.com\/2026\/11\/11\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\/"},"author":{"name":"info@scondar.com","@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3"},"headline":"POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals","datePublished":"2026-11-11T11:02:16+00:00","dateModified":"2026-11-19T05:18:49+00:00","mainEntityOfPage":{"@id":"https:\/\/www.scondar.com\/2026\/11\/11\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\/"},"wordCount":1320,"articleSection":["Uncategorized"],"inLanguage":"ru-RU"},{"@type":"WebPage","@id":"https:\/\/www.scondar.com\/2026\/11\/11\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\/","url":"https:\/\/www.scondar.com\/2026\/11\/11\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\/","name":"POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals - SCONDAR","isPartOf":{"@id":"https:\/\/www.scondar.com\/#website"},"datePublished":"2026-11-11T11:02:16+00:00","dateModified":"2026-11-19T05:18:49+00:00","author":{"@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3"},"breadcrumb":{"@id":"https:\/\/www.scondar.com\/2026\/11\/11\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.scondar.com\/2026\/11\/11\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.scondar.com\/2026\/11\/11\/pos-machine-harness-connector-selection-wire-to-board-solutions-for-retail-point-of-sale-terminals\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.scondar.com\/"},{"@type":"ListItem","position":2,"name":"POS Machine Harness Connector Selection: Wire-to-Board Solutions for Retail Point-of-Sale Terminals"}]},{"@type":"WebSite","@id":"https:\/\/www.scondar.com\/#website","url":"https:\/\/www.scondar.com\/","name":"SCONDAR","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.scondar.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Person","@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3","name":"info@scondar.com","image":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","caption":"info@scondar.com"},"sameAs":["https:\/\/www.scondar.com"],"url":"https:\/\/www.scondar.com\/ru\/author\/scondar-2\/"}]}},"_links":{"self":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/81004","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/comments?post=81004"}],"version-history":[{"count":1,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/81004\/revisions"}],"predecessor-version":[{"id":81005,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/81004\/revisions\/81005"}],"wp:attachment":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/media?parent=81004"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/categories?post=81004"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/tags?post=81004"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}