{"id":80870,"date":"2026-11-09T09:07:36","date_gmt":"2026-11-09T01:07:36","guid":{"rendered":"https:\/\/www.scondar.com\/?p=80870"},"modified":"2026-11-09T09:07:36","modified_gmt":"2026-11-09T01:07:36","slug":"patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution","status":"publish","type":"post","link":"https:\/\/www.scondar.com\/ru\/2026\/11\/09\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\/","title":{"rendered":"Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution"},"content":{"rendered":"<h1>Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution<\/h1>\n<h2>Application Context &amp; Design Challenge<\/h2>\n<p>Patient monitors \u2013 bedside units, transport monitors, and wearable vital-signs devices \u2013 pack several sensitive electronic functions into a small, frequently moved enclosure. A typical monitor routes low-voltage analog sensor signals, digital display data, and battery-derived DC power across four functional blocks: the main processing board, the color TFT\/LCD display module, the patient parameter boards (ECG, SpO2, NIBP, temperature), and the battery \/ DC-input power section.<\/p>\n<p>In our application lab, we frequently review patient monitor harness inquiries where engineers are evaluating alternative connector options against original reference designs. The recurring constraints are consistent: the device is carried between rooms and dropped on carts, so connectors must resist disengagement under shock and vibration; analog patient signals demand stable contact resistance and shielding where applicable; and the enclosure is densely packed, forcing fine-pitch interconnect on the display and sensor side while retaining a robust power connector on the battery side. A mismatch here typically surfaces as intermittent SpO2 readings, backlight flicker on the display, or battery contact failure after transport.<\/p>\n<h2>SCONDAR Wire-to-Board Connector Matching for This Application<\/h2>\n<p>For patient monitor harness designs, SCONDAR&#8217;s<a href=\"https:\/\/www.scondar.com\/wire-to-board\/\">wire-to-board connector portfolio<\/a>covers pitch ranges from 0.8 mm to 7.5 mm with multiple locking options. The following series are the ones we most often recommend for bedside and transport monitor subsystems, each engineered as a footprint-compatible alternative to the corresponding industry-standard reference connector:<\/p>\n<ul>\n<li>SCT1258 \u2013 footprint-compatible alternative to JST GH, 1.25 mm pitch, 1 A, secure lock \u2013 used on patient parameter boards where mating integrity must survive repeated cable reconnection.<\/li>\n<\/ul>\n<ul>\n<li>SCT1252 \u2013 footprint-compatible alternative to Hirose DF13, 1.25 mm pitch, 1 A, low-profile SMT, dual-row \u2013 used for display-module to main-board signal routing.<\/li>\n<\/ul>\n<ul>\n<li>SCT2001 \u2013 footprint-compatible alternative to JST PH, 2.0 mm pitch, 2 A, 250 V \u2013 used on battery and DC-input power distribution.<\/li>\n<\/ul>\n<ul>\n<li>SCT1501 \u2013 footprint-compatible alternative to JST ZH, 1.5 mm pitch, 1 A \u2013 used for auxiliary peripherals such as temperature probes and network modules.<\/li>\n<\/ul>\n<ul>\n<li>SCT1201 \u2013 footprint-compatible alternative to Hirose DF57, 1.2 mm pitch, 2 A, reinforced lock, \u221240 \u00b0C to +85 \u00b0C \u2013 used in transport monitors where shock and vibration are more severe.<\/li>\n<\/ul>\n<h2>Technical Specification Overview<\/h2>\n<p>All current, voltage, and temperature figures below are taken directly from SCONDAR&#8217;s published basic and performance parameters for each series.<\/p>\n<table>\n<tr>\n<th>SCONDAR Series<\/th>\n<th>Original Reference<\/th>\n<th>Pitch<\/th>\n<th>Current Rating<\/th>\n<th>Voltage Rating<\/th>\n<th>Temperature Range<\/th>\n<th>Key Feature<\/th>\n<\/tr>\n<tr>\n<td>SCT1258<\/td>\n<td>JST GH<\/td>\n<td>1.25 mm<\/td>\n<td>1 A<\/td>\n<td>50 V<\/td>\n<td>\u221225 \u00b0C to +85 \u00b0C<\/td>\n<td>Secure lock; AWG #26\u2013#30; sensor-board mating<\/td>\n<\/tr>\n<tr>\n<td>SCT1252<\/td>\n<td>Hirose DF13<\/td>\n<td>1.25 mm<\/td>\n<td>1 A<\/td>\n<td>125 V<\/td>\n<td>\u221240 \u00b0C to +85 \u00b0C<\/td>\n<td>Low-profile SMT; dual-row; display signal<\/td>\n<\/tr>\n<tr>\n<td>SCT2001<\/td>\n<td>JST PH<\/td>\n<td>2.0 mm<\/td>\n<td>2 A<\/td>\n<td>250 V<\/td>\n<td>\u221225 \u00b0C to +85 \u00b0C<\/td>\n<td>AWG #22\u2013#28; battery \/ DC power<\/td>\n<\/tr>\n<tr>\n<td>SCT1501<\/td>\n<td>JST ZH<\/td>\n<td>1.5 mm<\/td>\n<td>1 A<\/td>\n<td>50 V<\/td>\n<td>\u221225 \u00b0C to +85 \u00b0C<\/td>\n<td>Compact; auxiliary peripherals<\/td>\n<\/tr>\n<tr>\n<td>SCT1201<\/td>\n<td>Hirose DF57<\/td>\n<td>1.2 mm<\/td>\n<td>2 A<\/td>\n<td>50 V<\/td>\n<td>\u221240 \u00b0C to +85 \u00b0C<\/td>\n<td>Reinforced lock; shock \/ vibration<\/td>\n<\/tr>\n<\/table>\n<h2>Design-In Considerations: Mechanical &amp; Process<\/h2>\n<h3>Pitch, wire gauge, and signal integrity<\/h3>\n<p>The display module benefits from the 1.25 mm SCT1252 (AWG #28\u2013#32), where dual-row density fits the display FPC-to-board transition without adding stack height. Patient parameter boards use the SCT1258 (AWG #26\u2013#30), whose secure lock survives repeated lead-wire connection and disconnection during sensor replacement. The battery and DC-input section uses the 2.0 mm SCT2001 (AWG #22\u2013#28), where larger conductors carry 2 A load currents with margin. For transport monitors exposed to cart shock, the SCT1201 (AWG #28\u2013#32) with its reinforced lock is preferred over friction-only alternatives.<\/p>\n<h3>Locking and polarization<\/h3>\n<p>Patient monitors are repeatedly moved, and lead wires are pulled during patient care. The SCT1258 secure lock and SCT1201 reinforced lock both provide a positive tactile click and polarization features that prevent mis-mating during reassembly. On the static display connection, the low-profile SCT1252 does not require a high-profile lock; its dual-row contact arrangement is sufficient for a fixed internal link.<\/p>\n<h3>Termination method and harness assembly<\/h3>\n<p>For SCT1258, SCT1252, and SCT2001, SCONDAR applies crimp termination using automated crimping presses, with pull-out force and crimp height verified per terminal to hold consistency across production lots. For high-volume monitor programs, the harness side can be pre-terminated to specified lengths and 100% continuity and contact-resistance tested before shipment, reducing assembly time on the OEM line.<\/p>\n<h3>Material and environmental notes<\/h3>\n<p>Housings across these series use UL 94V-0 rated thermoplastics, and terminals are phosphor-bronze or brass with tin plating (selective gold available for high-cycle contacts). The operating temperature range of \u221225 \u00b0C to +85 \u00b0C (SCT1201 extends to \u221240 \u00b0C) covers typical hospital ward and transport environments. Contact resistance is held at 20\u201330 m\u03a9 maximum, supporting stable analog signal acquisition over the product&#8217;s service life.<\/p>\n<h2>SCONDAR at a Glance<\/h2>\n<p>SCONDAR is a China-based manufacturer of custom wire harnesses and wire-to-board and wire-to-wire connectors, with Pin-to-Pin compatible alternatives across JST, Hirose, TE, JAE, and Dupont families from 0.8 mm to 7.5 mm pitch.<\/p>\n<p>In-house production runs the full wire-processing chain: cutting, stripping, crimping, tin-dipping, soldering, housing insertion, overmolding, and labeling, supported by automated crimping presses, automatic soldering machines, and injection molding equipment.<\/p>\n<p>SCONDAR backs every order with 9 utility patents, a 98.4% on-time delivery rate, and one-piece free sampling, plus a design-to-production service flow for custom harness programs.<\/p>\n<h2>Quality Assurance &amp; Supply Chain<\/h2>\n<p>SCONDAR maintains an ISO 9001:2015 quality management system (certificate No. 02816Q11592RS) and holds UL\/CUL recognition (File E538921) together with SGS-verified RoHS and REACH compliance for the connector and harness portfolio. Incoming, in-process, and final inspection cover pull-out force, crimp height, contact resistance, insulation resistance, and withstanding voltage.<\/p>\n<p>On the supply side, SCONDAR&#8217;s manufacturing operation runs at approximately 80% automation across cutting, crimping, insertion, and testing, supporting consistent lot-to-lot quality and stable lead times. We have delivered interconnect solutions to over 2,000+ global electronics and industrial equipment manufacturers since 2008.<\/p>\n<p>For production environments that prioritize assembly consistency, SCONDAR also provides<a href=\"https:\/\/www.scondar.com\/cable-assemblies\/\">custom cable assembly services<\/a>that combine these connectors with pre-terminated wires in specified lengths. For monitor signal paths that must join two cable segments without an intermediate board, the<a href=\"https:\/\/www.scondar.com\/wire-to-wire\/\">wire-to-wire connector portfolio<\/a>covers the mating-pair options.<\/p>\n<h2>Frequently Asked Questions<\/h2>\n<h3>How do I verify that a SCONDAR alternative does not require a PCB layout change?<\/h3>\n<p>Each series listed above is engineered as a footprint-compatible alternative to a named industry reference \u2013 SCT1258 to JST GH, SCT1252 to Hirose DF13, SCT2001 to JST PH, SCT1501 to JST ZH, and SCT1201 to Hirose DF57. Footprint, pin pitch, and mating orientation follow the original reference so the existing land pattern can be reused. We recommend confirming the specific header style (top-entry vs. side-entry, SMT vs. through-hole) against your board stack-up; our<a href=\"https:\/\/www.scondar.com\/contact\/\">application engineering team<\/a>is available for design-in support and sample inquiries.<\/p>\n<h3>What should I expect from these connectors in long-term patient monitor operation?<\/h3>\n<p>The relevant failure modes in a patient monitor are contact-resistance drift on analog sensor channels and mechanical wear from repeated lead-wire connection. The secure and reinforced locks on SCT1258 and SCT1201 maintain mating under repeated motion, and contacts are qualified within the stated temperature and current ratings. For programs with extended service-life targets, we recommend requesting the relevant lifecycle and environmental test data (insertion\/withdrawal cycle, thermal cycling, shock and vibration) so the chosen series can be validated against your device&#8217;s reliability specification.<\/p>\n<p>Do you have a requirement for the connectors and harnesses featured in this article, or need a similar custom wiring harness and connector solution? Send your application details to inquiry@scondar.com to request a free sample kit for in-house validation.<\/p>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How do I verify that a SCONDAR alternative does not require a PCB layout change?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Each series listed above is engineered as a footprint-compatible alternative to a named industry reference \u2013 SCT1258 to JST GH, SCT1252 to Hirose DF13, SCT2001 to JST PH, SCT1501 to JST ZH, and SCT1201 to Hirose DF57. Footprint, pin pitch, and mating orientation follow the original reference so the existing land pattern can be reused. We recommend confirming the specific header style (top-entry vs. side-entry, SMT vs. through-hole) against your board stack-up; our application engineering team is available for design-in support and sample inquiries.\"}}, {\"@type\": \"Question\", \"name\": \"What should I expect from these connectors in long-term patient monitor operation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The relevant failure modes in a patient monitor are contact-resistance drift on analog sensor channels and mechanical wear from repeated lead-wire connection. The secure and reinforced locks on SCT1258 and SCT1201 maintain mating under repeated motion, and contacts are qualified within the stated temperature and current ratings. For programs with extended service-life targets, we recommend requesting the relevant lifecycle and environmental test data (insertion\/withdrawal cycle, thermal cycling, shock and vibration) so the chosen series can be validated against your device's reliability specification.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution Application Context &amp; Design Challenge Patient monitors \u2013 bedside units, transport monitors, and wearable vital-signs devices \u2013 pack several sensitive electronic functions into a small, frequently moved enclosure. A typical monitor routes low-voltage analog sensor signals, digital display data, and battery-derived DC power across [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-80870","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution - SCONDAR<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.scondar.com\/ru\/2026\/11\/09\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution - SCONDAR\" \/>\n<meta property=\"og:description\" content=\"Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution Application Context &amp; Design Challenge Patient monitors \u2013 bedside units, transport monitors, and wearable vital-signs devices \u2013 pack several sensitive electronic functions into a small, frequently moved enclosure. A typical monitor routes low-voltage analog sensor signals, digital display data, and battery-derived DC power across [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.scondar.com\/ru\/2026\/11\/09\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\/\" \/>\n<meta property=\"og:site_name\" content=\"SCONDAR\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-09T01:07:36+00:00\" \/>\n<meta name=\"author\" content=\"info@scondar.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c\" \/>\n\t<meta name=\"twitter:data1\" content=\"info@scondar.com\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/09\\\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/09\\\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\\\/\"},\"author\":{\"name\":\"info@scondar.com\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\"},\"headline\":\"Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution\",\"datePublished\":\"2026-11-09T01:07:36+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/09\\\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\\\/\"},\"wordCount\":1191,\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"ru-RU\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/09\\\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\\\/\",\"url\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/09\\\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\\\/\",\"name\":\"Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution - SCONDAR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#website\"},\"datePublished\":\"2026-11-09T01:07:36+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/09\\\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/09\\\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/11\\\/09\\\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.scondar.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#website\",\"url\":\"https:\\\/\\\/www.scondar.com\\\/\",\"name\":\"SCONDAR\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.scondar.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\",\"name\":\"info@scondar.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"caption\":\"info@scondar.com\"},\"sameAs\":[\"https:\\\/\\\/www.scondar.com\"],\"url\":\"https:\\\/\\\/www.scondar.com\\\/ru\\\/author\\\/scondar-2\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution - SCONDAR","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.scondar.com\/ru\/2026\/11\/09\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\/","og_locale":"ru_RU","og_type":"article","og_title":"Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution - SCONDAR","og_description":"Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution Application Context &amp; Design Challenge Patient monitors \u2013 bedside units, transport monitors, and wearable vital-signs devices \u2013 pack several sensitive electronic functions into a small, frequently moved enclosure. A typical monitor routes low-voltage analog sensor signals, digital display data, and battery-derived DC power across [&hellip;]","og_url":"https:\/\/www.scondar.com\/ru\/2026\/11\/09\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\/","og_site_name":"SCONDAR","article_published_time":"2026-11-09T01:07:36+00:00","author":"info@scondar.com","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c":"info@scondar.com"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.scondar.com\/2026\/11\/09\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\/#article","isPartOf":{"@id":"https:\/\/www.scondar.com\/2026\/11\/09\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\/"},"author":{"name":"info@scondar.com","@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3"},"headline":"Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution","datePublished":"2026-11-09T01:07:36+00:00","mainEntityOfPage":{"@id":"https:\/\/www.scondar.com\/2026\/11\/09\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\/"},"wordCount":1191,"articleSection":["Uncategorized"],"inLanguage":"ru-RU"},{"@type":"WebPage","@id":"https:\/\/www.scondar.com\/2026\/11\/09\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\/","url":"https:\/\/www.scondar.com\/2026\/11\/09\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\/","name":"Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution - SCONDAR","isPartOf":{"@id":"https:\/\/www.scondar.com\/#website"},"datePublished":"2026-11-09T01:07:36+00:00","author":{"@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3"},"breadcrumb":{"@id":"https:\/\/www.scondar.com\/2026\/11\/09\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.scondar.com\/2026\/11\/09\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.scondar.com\/2026\/11\/09\/patient-monitor-harness-connector-selection-display-sensor-board-and-power-distribution\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.scondar.com\/"},{"@type":"ListItem","position":2,"name":"Patient Monitor Harness Connector Selection: Display, Sensor Board, and Power Distribution"}]},{"@type":"WebSite","@id":"https:\/\/www.scondar.com\/#website","url":"https:\/\/www.scondar.com\/","name":"SCONDAR","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.scondar.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Person","@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3","name":"info@scondar.com","image":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","caption":"info@scondar.com"},"sameAs":["https:\/\/www.scondar.com"],"url":"https:\/\/www.scondar.com\/ru\/author\/scondar-2\/"}]}},"_links":{"self":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/80870","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/comments?post=80870"}],"version-history":[{"count":1,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/80870\/revisions"}],"predecessor-version":[{"id":80871,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/80870\/revisions\/80871"}],"wp:attachment":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/media?parent=80870"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/categories?post=80870"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/tags?post=80870"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}