{"id":80845,"date":"2026-10-31T19:42:48","date_gmt":"2026-10-31T11:42:48","guid":{"rendered":"https:\/\/www.scondar.com\/?p=80845"},"modified":"2026-11-05T14:15:46","modified_gmt":"2026-11-05T06:15:46","slug":"network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules","status":"publish","type":"post","link":"https:\/\/www.scondar.com\/ru\/2026\/10\/31\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\/","title":{"rendered":"Network Splitter Connector Selection: Wire-to-Board Solutions for Routers, Gateways, and 5G Base Station Modules"},"content":{"rendered":"<h2>Network equipment does not get switched off. A router in a home runs continuously for years. An industrial Ethernet splitter in a factory automation cabinet runs through thermal cycles, power fluctuations, and vibration\u2014without anyone touching it. When these devices fail, the cause is rarely a catastrophic component failure. More often, it is a connector whose contact resistance drifted upward over thousands of thermal cycles until the signal became unreliable. This guide focuses on the connector specifications that determine whether a network device keeps running reliably or degrades silently over its service life.<\/h2>\n<h2>What actually kills connectors in network equipment<\/h2>\n<ul>\n<li>Thermal cycling: Every power-on cycle causes slight expansion and contraction at the contact interface. Over thousands of cycles, friction-lock contacts can work loose, increasing contact resistance. Box-contact designs resist this better because the contact geometry holds the terminal in place.<\/li>\n<li>Humidity: Condensation inside enclosed cabinets (especially in humid climates or unconditioned spaces) can corrode contact surfaces. Connectors with UL94V-0 rated PA66 housings resist moisture absorption better than standard nylon housings.<\/li>\n<li>Vibration (industrial environments): Factory automation cabinets and base station modules experience continuous low-frequency vibration. Friction-lock connectors are prone to micro-movement under vibration loading.<\/li>\n<li>Solder joint fatigue (thermal mismatch): Surface-mount connectors on boards that experience wide temperature swings are prone to solder joint cracking over time. THR (through-hole reflow) variants resist this better.<\/li>\n<\/ul>\n<h2>The SCT1257: box-contact design for long-term reliability<\/h2>\n<p>The network splitter connector selected for an always-on industrial application must have box-contact geometry\u2014this is what maintains stable contact resistance over thousands of thermal cycles.<\/p>\n<p>Network splitter connector selection is fundamentally about long-term contact stability\u2014not the running current, but the accumulated effect of thermal cycling on contact resistance over the service life of the network splitter connector installation.<\/p>\n<p>The SCONDAR SCT1257 (JAE IL-Z compatible, 1.25mm pitch, 1A) is built around a box-contact geometry\u2014the contact body wraps around the terminal, preventing deformation during insertion and resisting the thermal-cycle-induced loosening that plagues open-contact designs. For a network device expected to run 24\/7 for five or more years, the box-contact architecture is the specification that matters for long-term contact stability.<\/p>\n<p>For network splitter connector installations where vibration is a factor, the positive-lock housing is not optional\u2014it is the feature that distinguishes a reliable network splitter connector from one that drifts over time.<\/p>\n<p>The SCT1257 network splitter connector uses a box-contact geometry that resists the vibration and thermal cycling stress that causes contact resistance drift in a network splitter connector deployed in a 24\/7 always-on environment.<\/p>\n<p>Browse the complete <a href=\"https:\/\/www.scondar.com\/ru\/%d0%bf%d1%80%d0%be%d0%b2%d0%be%d0%b4-%d0%ba-%d0%bf%d0%bb%d0%b0%d1%82%d0%b5\/\">SCONDAR wire-to-board connector range for networking equipment<\/a>\u2014including connectors for routers, gateways, and 5G base stations.<\/p>\n<h2>Choosing the right operating temperature range<\/h2>\n<p>The SCT1257\u2019s \u221225\u00b0C to +105\u00b0C operating range covers most enclosed network cabinet environments. However, the specification to verify is the actual ambient temperature inside the cabinet under worst-case conditions\u2014not the datasheet ambient rating of the network device. A router rated for 40\u00b0C ambient might sit inside a sealed cabinet that reaches 55\u00b0C in summer. Check the cabinet thermal profile before selecting a connector.<\/p>\n<p>For network splitter connector installations in industrial environments, the vibration loading from adjacent machinery is often the governing stress\u2014not the electrical rating of the network splitter connector itself. Verify the vibration profile with your mechanical team before specifying the locking mechanism.<\/p>\n<h2>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>SCONDAR SCT1257<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Original Reference<\/td>\n<td>JAE IL-Z<\/td>\n<\/tr>\n<tr>\n<td>Pitch<\/td>\n<td>1.25 mm<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u0435\u043a\u0443\u0449\u0438\u0439<\/td>\n<td>1A per contact<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td>\n<td>Standard networking class<\/td>\n<\/tr>\n<tr>\n<td>Temp<\/td>\n<td>\u221225\u00b0C ~ +105\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u0416\u0438\u043b\u044c\u0435<\/td>\n<td>UL94V-0 rated PA66<\/td>\n<\/tr>\n<tr>\n<td>Termination<\/td>\n<td>Crimp-style<\/td>\n<\/tr>\n<tr>\n<td>Positions<\/td>\n<td>2 to 15 (single-row)<\/td>\n<\/tr>\n<tr>\n<td>\u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/td>\n<td>Box-contact; JAE IL-Z footprint compatible; flame-retardant<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Design-In Considerations<\/h2>\n<h3>Box-contact vs crimp: does it affect manufacturing?<\/h3>\n<p>The SCT1257 uses crimp-style terminals, which requires a crimping process in the harness manufacturing workflow. If your production process is set up for insulation displacement (IDC) connectors or pre-crimped leads, factor in the crimping setup cost. The upside is consistent pull-out force and contact resistance\u2014crimp connectors are more repeatable than hand-soldered alternatives for high-volume production.<\/p>\n<p>For 5G base station modules with outdoor exposure, the network splitter connector must be paired with appropriate enclosure sealing\u2014the PA66 housing resists moisture absorption, but it is not itself a sealed network splitter connector.<\/p>\n<h3>Outdoor 5G base station applications<\/h3>\n<p>For outdoor 5G base station modules exposed to direct precipitation, the standard SCT1257 PA66 housing may need pairing with enclosure-level sealing. The PA66 housing itself is not sealed\u2014 it protects the contact mechanism from humidity and condensation inside a sealed enclosure. Contact SCONDAR\u2019s application team to discuss whether a sealed connector variant is needed for your specific outdoor installation.<\/p>\n<p>Have a specific network splitter connector application? Note the equipment type, the operating environment, and whether the installation is indoor or outdoor in the comments. Our team follows up on network splitter connector inquiries with application-specific recommendations.<\/p>\n<h2>Quality Assurance &amp; Supply Chain<\/h2>\n<ul>\n<li>ISO 9001:2015 quality management (Certificate No. 02816Q11592RS); automated production at Dongguan facility<\/li>\n<li>RoHS and REACH compliant; flame-retardant housing verified per UL94V-0<\/li>\n<li>Free sample kits and product drawings for fit verification; 3D STEP files available on request<\/li>\n<li>Delivered interconnect solutions to over 2,000+ global electronics and industrial equipment manufacturers since 2008<\/li>\n<\/ul>\n<h2>Frequently Asked Questions<\/h2>\n<h3>Q1: Our network router runs 24\/7 in a sealed cabinet with limited ventilation\u2014what connector temperature rating is appropriate?<\/h3>\n<p>The relevant temperature is the connector\u2019s actual operating temperature at the PCB\u2014not the device\u2019s ambient rating. A sealed cabinet in direct sunlight can run 15\u201320\u00b0C above ambient. The SCT1257\u2019s \u221225\u00b0C to +105\u00b0C range gives meaningful headroom, but verify the worst-case internal cabinet temperature for your installation. If the connector hotspot at the PCB exceeds the rating, derating the current or moving to a higher-temperature connector variant is necessary.<\/p>\n<h3>Q2: We need a connector for a multi-port Ethernet splitter with 12 ports\u2014does the SCT1257 support enough positions?<\/h3>\n<p>Yes. The SCT1257 is available in single-row configurations from 2 to 15 positions. For a 12-port splitter, a 12-position SCT1257 header covers all ports on a single connector. Verify the PCB footprint requirements against the SCONDAR product drawing\u2014a 12-position header has a longer body than a 2-position one, and the mounting boss location matters for board layout. Free sample kits and 3D STEP files are available to confirm physical fit before production qualification.<\/p>\n<p>Building a new network product and need to confirm connector footprint, thermal derating, or pull-out force for your specific application? Describe the equipment type, board layout, and operating environment in the comments\u2014our engineering team follows up on design-in inquiries with application-specific recommendations.<\/p>\n<p>Free sample kits and detailed specifications are available\u2014<a href=\"https:\/\/www.scondar.com\/ru\/%d1%81%d0%b2%d1%8f%d0%b7%d0%b0%d1%82%d1%8c%d1%81%d1%8f-%d1%81\/\">request your kit here.<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Network equipment does not get switched off. A router in a home runs continuously for years. An industrial Ethernet splitter in a factory automation cabinet runs through thermal cycles, power fluctuations, and vibration\u2014without anyone touching it. When these devices fail, the cause is rarely a catastrophic component failure. More often, it is a connector whose [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-80845","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Network Splitter Connector Selection: Wire-to-Board Solutions for Routers, Gateways, and 5G Base Station Modules - SCONDAR<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.scondar.com\/ru\/2026\/10\/31\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Network Splitter Connector Selection: Wire-to-Board Solutions for Routers, Gateways, and 5G Base Station Modules - SCONDAR\" \/>\n<meta property=\"og:description\" content=\"Network equipment does not get switched off. A router in a home runs continuously for years. An industrial Ethernet splitter in a factory automation cabinet runs through thermal cycles, power fluctuations, and vibration\u2014without anyone touching it. When these devices fail, the cause is rarely a catastrophic component failure. More often, it is a connector whose [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.scondar.com\/ru\/2026\/10\/31\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\/\" \/>\n<meta property=\"og:site_name\" content=\"SCONDAR\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-31T11:42:48+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-05T06:15:46+00:00\" \/>\n<meta name=\"author\" content=\"info@scondar.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c\" \/>\n\t<meta name=\"twitter:data1\" content=\"info@scondar.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 \u043c\u0438\u043d\u0443\u0442\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/31\\\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/31\\\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\\\/\"},\"author\":{\"name\":\"info@scondar.com\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\"},\"headline\":\"Network Splitter Connector Selection: Wire-to-Board Solutions for Routers, Gateways, and 5G Base Station Modules\",\"datePublished\":\"2026-10-31T11:42:48+00:00\",\"dateModified\":\"2026-11-05T06:15:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/31\\\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\\\/\"},\"wordCount\":1094,\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"ru-RU\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/31\\\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\\\/\",\"url\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/31\\\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\\\/\",\"name\":\"Network Splitter Connector Selection: Wire-to-Board Solutions for Routers, Gateways, and 5G Base Station Modules - SCONDAR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#website\"},\"datePublished\":\"2026-10-31T11:42:48+00:00\",\"dateModified\":\"2026-11-05T06:15:46+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/31\\\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/31\\\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/31\\\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.scondar.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Network Splitter Connector Selection: Wire-to-Board Solutions for Routers, Gateways, and 5G Base Station Modules\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#website\",\"url\":\"https:\\\/\\\/www.scondar.com\\\/\",\"name\":\"SCONDAR\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.scondar.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\",\"name\":\"info@scondar.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"caption\":\"info@scondar.com\"},\"sameAs\":[\"https:\\\/\\\/www.scondar.com\"],\"url\":\"https:\\\/\\\/www.scondar.com\\\/ru\\\/author\\\/scondar-2\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Network Splitter Connector Selection: Wire-to-Board Solutions for Routers, Gateways, and 5G Base Station Modules - SCONDAR","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.scondar.com\/ru\/2026\/10\/31\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\/","og_locale":"ru_RU","og_type":"article","og_title":"Network Splitter Connector Selection: Wire-to-Board Solutions for Routers, Gateways, and 5G Base Station Modules - SCONDAR","og_description":"Network equipment does not get switched off. A router in a home runs continuously for years. An industrial Ethernet splitter in a factory automation cabinet runs through thermal cycles, power fluctuations, and vibration\u2014without anyone touching it. When these devices fail, the cause is rarely a catastrophic component failure. More often, it is a connector whose [&hellip;]","og_url":"https:\/\/www.scondar.com\/ru\/2026\/10\/31\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\/","og_site_name":"SCONDAR","article_published_time":"2026-10-31T11:42:48+00:00","article_modified_time":"2026-11-05T06:15:46+00:00","author":"info@scondar.com","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c":"info@scondar.com","\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f":"5 \u043c\u0438\u043d\u0443\u0442"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.scondar.com\/2026\/10\/31\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\/#article","isPartOf":{"@id":"https:\/\/www.scondar.com\/2026\/10\/31\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\/"},"author":{"name":"info@scondar.com","@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3"},"headline":"Network Splitter Connector Selection: Wire-to-Board Solutions for Routers, Gateways, and 5G Base Station Modules","datePublished":"2026-10-31T11:42:48+00:00","dateModified":"2026-11-05T06:15:46+00:00","mainEntityOfPage":{"@id":"https:\/\/www.scondar.com\/2026\/10\/31\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\/"},"wordCount":1094,"articleSection":["Uncategorized"],"inLanguage":"ru-RU"},{"@type":"WebPage","@id":"https:\/\/www.scondar.com\/2026\/10\/31\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\/","url":"https:\/\/www.scondar.com\/2026\/10\/31\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\/","name":"Network Splitter Connector Selection: Wire-to-Board Solutions for Routers, Gateways, and 5G Base Station Modules - SCONDAR","isPartOf":{"@id":"https:\/\/www.scondar.com\/#website"},"datePublished":"2026-10-31T11:42:48+00:00","dateModified":"2026-11-05T06:15:46+00:00","author":{"@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3"},"breadcrumb":{"@id":"https:\/\/www.scondar.com\/2026\/10\/31\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.scondar.com\/2026\/10\/31\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.scondar.com\/2026\/10\/31\/network-splitter-connector-selection-wire-to-board-solutions-for-routers-gateways-and-5g-base-station-modules\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.scondar.com\/"},{"@type":"ListItem","position":2,"name":"Network Splitter Connector Selection: Wire-to-Board Solutions for Routers, Gateways, and 5G Base Station Modules"}]},{"@type":"WebSite","@id":"https:\/\/www.scondar.com\/#website","url":"https:\/\/www.scondar.com\/","name":"SCONDAR","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.scondar.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Person","@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3","name":"info@scondar.com","image":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","caption":"info@scondar.com"},"sameAs":["https:\/\/www.scondar.com"],"url":"https:\/\/www.scondar.com\/ru\/author\/scondar-2\/"}]}},"_links":{"self":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/80845","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/comments?post=80845"}],"version-history":[{"count":2,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/80845\/revisions"}],"predecessor-version":[{"id":80863,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/80845\/revisions\/80863"}],"wp:attachment":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/media?parent=80845"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/categories?post=80845"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/tags?post=80845"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}