{"id":80811,"date":"2026-10-26T13:45:01","date_gmt":"2026-10-26T05:45:01","guid":{"rendered":"https:\/\/www.scondar.com\/?p=80811"},"modified":"2026-10-26T13:45:01","modified_gmt":"2026-10-26T05:45:01","slug":"wire-to-board-connectors-for-network-extension-cables-selection-guide","status":"publish","type":"post","link":"https:\/\/www.scondar.com\/ru\/2026\/10\/26\/wire-to-board-connectors-for-network-extension-cables-selection-guide\/","title":{"rendered":"Wire-to-Board Connectors for Network Extension Cables: Selection Guide"},"content":{"rendered":"<h2>Network extension cables are a critical yet often overlooked component in structured cabling infrastructure. Whether extending a run between a router and a switch in a server rack, bridging signal connections across industrial control cabinets, or connecting peripheral network devices in a commercial building, the connector at each termination point must reliably preserve signal integrity across extended cable paths. This article examines the connector selection considerations specific to network extension cable applications, with a focus on how compact wire-to-board solutions from SCONDAR can address these requirements.<\/h2>\n<h2>The Application Context: Why Connector Selection Matters in Network Extension Cables<\/h2>\n<p>A network extension cable is, in principle, a straightforward assembly: conductor, insulation, shielding, and two termination connectors. In practice, however, the connector decision is where most design-in challenges arise\u2014particularly when the extension must interface with PCB-mounted headers inside active network equipment rather than simply terminating at a patch panel.<\/p>\n<p>Common design challenges in network extension cable applications include:<\/p>\n<ul>\n<li>Space constraints inside compact networking equipment: Consumer-grade routers, managed switches, and PoE (Power over Ethernet) devices increasingly feature miniaturized PCBs with tightly spaced headers. The connector must fit a defined PCB footprint without encroaching on adjacent components.<\/li>\n<li>Signal integrity at extended cable runs: Longer cable paths amplify the importance of low contact resistance at the termination point. Any incremental resistance introduced at a connector junction adds to the cumulative insertion loss of the run.<\/li>\n<li>Vibration and mechanical disturbance: Network equipment fans, especially in server environments, create continuous low-frequency vibration. A connector with insufficient retention force can work loose over time, causing intermittent connectivity.<\/li>\n<li>Assembly efficiency at scale: When producing network extension cables in volume\u2014whether for OEM integration or after-market accessories\u2014termination speed directly affects cost. Connectors that support automated or semi-automated assembly processes deliver a measurable economic advantage.<\/li>\n<\/ul>\n<p>Temperature variation in non-conditioned environments: Extension cables serving outdoor access points, industrial Ethernet switches, or PoE-powered surveillance cameras must operate across a wide temperature range without degradation of mechanical or electrical performance.<\/p>\n<p>Understanding these constraints helps frame the evaluation criteria for connector selection.<\/p>\n<h2>SCONDAR Product Matching for Network Extension Cable Applications<\/h2>\n<p>SCONDAR&#x27;s wire-to-board connector portfolio covers pitch dimensions from 0.8 mm to 7.5 mm, spanning signal-level to high-current configurations. For network extension cable applications\u2014particularly those terminating at compact headers inside networking equipment\u2014two series are most frequently evaluated by design engineers:<\/p>\n<h3>SCONDAR SCT0802 (Compatible with Hirose DF52)<\/h3>\n<p>The SCT0802 series occupies a uniquely effective position for network extension cable design. At 0.8 mm pitch, it is among the most compact wire-to-board connectors available in the SCONDAR lineup, making it suitable for header connections in space-constrained networking devices such as compact routers, access points, and PoE injectors.<\/p>\n<p>Key characteristics relevant to network extension cable applications:<\/p>\n<ul>\n<li>Compact form factor: The 0.8 mm pitch and box-shaped contact design allow the connector to be placed in tight PCB areas without interfering with neighboring components.<\/li>\n<li>Robust mechanical construction: The box-shaped contact geometry prevents contact deformation during mating and unmating\u2014a common failure mode in connectors subjected to repeated assembly and field servicing.<\/li>\n<li>Visual mating confirmation: A fully mated plug and receptacle can be verified visually, eliminating ambiguity during cable installation and maintenance.<\/li>\n<li>Wide temperature rating: Operating range from \u221240\u00b0C to +85\u00b0C supports deployment in both climate-controlled indoor environments and harsher conditions such as outdoor enclosures or industrial facilities.<\/li>\n<\/ul>\n<p>AWG #28\u201332 compatibility: Designed for ultra-fine wire gauges commonly used in network cable assemblies, enabling lightweight and flexible cable routing.<\/p>\n<p>The SCT0802 series is PCB-footprint compatible with the Hirose DF52, allowing direct substitution in existing designs without PCB layout changes.<\/p>\n<h3>SCONDAR SCT0800 (Compatible with JST SUR)<\/h3>\n<p>For network extension cable applications requiring an IDC (Insulation Displacement Contact) termination\u2014where the cable conductor is pierced by the contact without pre-stripping\u2014the SCT0800 series offers a streamlined alternative.<\/p>\n<ul>\n<li>IDC termination: Twin U-slot IDC sections pierce the cable insulation and make contact with the conductor simultaneously, eliminating the need for wire stripping, tinning, or soldering. This significantly accelerates field termination and supports automated production.<\/li>\n<li>3-point grip construction: The contact design provides reliable mechanical retention of the conductor, maintaining stable electrical contact under vibration.<\/li>\n<li>Side-entry profile: The side entry variant measures only 3.9 mm deep after PCB mounting, reducing the connector&#x27;s footprint on space-constrained boards.<\/li>\n<li>Current rating: 0.5 A \u2014 suitable for signal-level network connections including Ethernet differential pairs, status signaling, and low-power PoE auxiliary circuits.<\/li>\n<\/ul>\n<p>The SCT0800 is footprint-compatible with the JST SUR connector.<\/p>\n<h2>Technical Specification Overview<\/h2>\n<p>The following table summarizes the key technical parameters for SCONDAR&#x27;s primary network extension cable connector recommendations:<\/p>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>SCT0802 (Hirose DF52 Compatible)<\/th>\n<th>SCT0800 (JST SUR Compatible)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u0430\u044f \u043f\u043b\u043e\u0449\u0430\u0434\u043a\u0430<\/td>\n<td>0.8 mm<\/td>\n<td>0.8 mm<\/td>\n<\/tr>\n<tr>\n<td>\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0434\u043e\u043b\u0436\u043d\u043e\u0441\u0442\u0435\u0439<\/td>\n<td>2 to 20<\/td>\n<td>2 to 22<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u0435\u043a\u0443\u0449\u0438\u0439 \u0440\u0435\u0439\u0442\u0438\u043d\u0433<\/td>\n<td>1 A (max. 2.5 A at 2-pos., 28AWG)<\/td>\n<td>0.5 A<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td>\n<td>30 V<\/td>\n<td>30 V<\/td>\n<\/tr>\n<tr>\n<td>Temperature Range<\/td>\n<td>\u221240\u00b0C to +85\u00b0C<\/td>\n<td>\u221220\u00b0C to +85\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u0421\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432<\/td>\n<td>20 m\u03a9 max.<\/td>\n<td>20 m\u03a9 max.<\/td>\n<\/tr>\n<tr>\n<td>Insulation Resistance<\/td>\n<td>100 M\u03a9 min.<\/td>\n<td>100 M\u03a9 min.<\/td>\n<\/tr>\n<tr>\n<td>\u0412\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td>\n<td>200 V AC\/minute<\/td>\n<td>200 V AC\/minute<\/td>\n<\/tr>\n<tr>\n<td>\u0421\u0442\u0438\u043b\u044c \u0437\u0430\u0434\u0435\u043b\u043a\u0438<\/td>\n<td>Crimp<\/td>\n<td>IDC (Insulation Displacement)<\/td>\n<\/tr>\n<tr>\n<td>\u041a\u0430\u043b\u0438\u0431\u0440 \u043f\u0440\u043e\u0432\u043e\u0434\u0430<\/td>\n<td>AWG #28\u201332<\/td>\n<td>AWG #28\u201332<\/td>\n<\/tr>\n<tr>\n<td>Polarization<\/td>\n<td>Box-shaped keying<\/td>\n<td>Shrouded header, fully polarized<\/td>\n<\/tr>\n<tr>\n<td>Halogen-Free<\/td>\n<td>\u0414\u0430<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>Mating Visual Check<\/td>\n<td>\u0414\u0430<\/td>\n<td>Shrouded header<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>View full product specifications and download CAD models for the SCT0802 series<\/p>\n<h2>Design-In Considerations: Mechanical, Process, and Application Factors<\/h2>\n<h3>Wire Gauge and Pitch Compatibility<\/h3>\n<p>The 0.8 mm pitch of both the SCT0802 and SCT0800 series imposes a direct constraint on compatible wire gauges. The specified AWG #28\u201332 range reflects the physical dimensions of the contact slots in these ultra-compact connectors. Engineers specifying cable assemblies for these connectors should ensure that the conductor cross-section falls within this range; using oversized conductors can result in incomplete insertion, compromised contact force, or damage to the IDC slots (in the case of the SCT0800).<\/p>\n<p>For network extension cable applications carrying only signal-level Ethernet channels (e.g., 100BASE-TX or 1000BASE-T differential pairs), AWG #28 or #30 stranded conductors are typical and fully compatible with both the SCT0800 and SCT0802 series.<\/p>\n<h3>Crimp vs. IDC: Choosing the Right Termination Process<\/h3>\n<p>SCT0802 (Crimp termination): Requires pre-stripped conductors to be inserted into the crimp barrel of each contact, which is then deformed around the conductor by a calibrated crimping die. This process delivers high mechanical retention (measured as pull-out force) and is well-suited to production environments with automated crimping equipment. The crimp height and pull-out force should be verified against the product datasheet specifications during first-article qualification.<\/p>\n<p>SCT0800 (IDC termination): Eliminates the stripping step entirely. The twin U-slot IDC section pierces the cable insulation and establishes a gas-tight contact with the conductor in a single action. This is advantageous for:<\/p>\n<ul>\n<li>Field termination of extension cables (no special tools required at the installation site)<\/li>\n<li>Automated IDC termination machines, which can achieve high throughput with consistent quality<\/li>\n<li>Applications where avoiding solder or crimp tooling at the connector interface is preferred<\/li>\n<\/ul>\n<p>For network extension cables produced at scale for OEM integration, crimp termination (SCT0802) typically offers tighter process control. For after-market or field-serviceable cable assemblies, IDC termination (SCT0800) reduces assembly complexity.<\/p>\n<h3>Retention Force and Vibration Resistance<\/h3>\n<p>In rack-mounted or fan-ventilated network equipment, connectors are exposed to continuous low-level vibration. The SCT0802 series addresses this through its box-shaped contact geometry, which provides inherent resistance to contact displacement. For the highest-vibration environments (such as network equipment installed in industrial facilities with heavy machinery), adding a secondary retention mechanism\u2014such as a board-mounting clip or epoxy staking of the header\u2014is recommended.<\/p>\n<h3>Temperature Considerations for Outdoor and Industrial Network Extension<\/h3>\n<p>The extended temperature rating of the SCT0802 (\u221240\u00b0C to +85\u00b0C) makes it suitable for network extension cable deployments in environments subject to thermal cycling, including:<\/p>\n<ul>\n<li>Outdoor wireless access points and PoE-powered security cameras<\/li>\n<li>Industrial Ethernet switches in factory automation environments<\/li>\n<li>Telemetry and SCADA system extension cables in utility infrastructure<\/li>\n<\/ul>\n<p>For applications approaching the upper temperature limit, verify that the cable jacket material and any conformal coatings on the connector assembly are rated for the same temperature range.<\/p>\n<h2>Quality Assurance and Manufacturing Standards<\/h2>\n<p>SCONDAR&#x27;s manufacturing operations are guided by an ISO 9001:2015 quality management system (certificate No. 02816Q11592RS), providing a structured framework for process control, incoming material inspection, and outgoing product verification.<\/p>\n<p>All SCONDAR wire-to-board connectors are tested to verify compliance with the following parameters prior to shipment:<\/p>\n<ul>\n<li>Contact resistance: Maximum 20 m\u03a9, verified by daisy-chain resistance measurement<\/li>\n<li>Insulation resistance: Minimum 100 M\u03a9, verified per applicable test standard<\/li>\n<li>Withstanding voltage: 200 V AC\/minute without breakdown<\/li>\n<li>Pull-out force (crimp products): Verified to maintain consistent results within the specified range across sample lots<\/li>\n<\/ul>\n<p>SCONDAR&#x27;s product range covers pitch dimensions from 0.8 mm to 7.92 mm, with current ratings spanning 0.5 A to 34 A, enabling connector selection across the full spectrum of network equipment applications\u2014from signal-level header connections to power delivery in PoE-enabled infrastructure.<\/p>\n<p>For custom network extension cable assemblies, SCONDAR supports one-piece sample orders for first-article validation, and offers tooling customization for high-volume OEM programs.<\/p>\n<h2>Frequently Asked Questions<\/h2>\n<h3>FAQ 1: How do I verify that the SCONDAR SCT0802 is a drop-in replacement for the Hirose DF52 in my existing design?<\/h3>\n<p>The SCT0802 series is designed to be PCB-footprint compatible with the Hirose DF52, meaning the header pinout, mounting hole locations, and overall dimensions are matched to the original specification. To validate replacement compatibility:<\/p>\n<ol>\n<li>Download the CAD footprint drawing (STEP and DXF formats available on the SCONDAR product page) and import it into your PCB layout tool.<\/li>\n<li>Compare the footprint against your current Hirose DF52 land pattern. Key dimensions to verify include: contact pitch (0.8 mm), seating plane height, and header overall width.<\/li>\n<li>Confirm that your board thickness falls within the connector&#x27;s specified range (typically 1.0 mm to 1.6 mm for standard applications).<\/li>\n<\/ol>\n<p>Request a sample kit from SCONDAR to perform mechanical mating checks and, if applicable, functional testing with your network cable assembly.<\/p>\n<p>A footprint-compatible replacement means no PCB layout changes are required in most designs, significantly reducing the qualification workload.<\/p>\n<h3>FAQ 2: What is the expected operational lifespan of the SCT0802 connector in a network extension cable application?<\/h3>\n<p>Connector durability in network extension cable applications is typically evaluated through mating cycle testing and long-term environmental exposure. The SCT0802&#x27;s specifications should be reviewed against the specific requirements of your application, including:<\/p>\n<ul>\n<li>Mating frequency: If the cable assembly is mated and unmated frequently (e.g., in field-serviceable installations), the contact&#x27;s mechanical wear becomes the primary lifespan driver. SCONDAR conducts pull-out force testing after 100 mating cycles as part of its standard qualification protocol.<\/li>\n<li>Operating temperature: Extended exposure at temperatures near the upper limit (\u221240\u00b0C to +85\u00b0C range) accelerates degradation of polymer housing materials and contact plating. For applications in consistently high-temperature environments, consider connectors rated above the SCT0802&#x27;s 85\u00b0C upper limit.<\/li>\n<li>Vibration exposure: Sustained vibration (as found in server rooms with high-speed fans or industrial environments) can gradually reduce contact normal force. Use of a secondary board-retention mechanism is recommended for vibration-prone installations.<\/li>\n<\/ul>\n<p>SCONDAR provides detailed reliability data upon request for OEM qualification programs.<\/p>\n<p>Over an extended cable run, the connector quietly decides whether your signal arrives clean or degraded\u2014contact resistance and shield continuity matter more than raw pin count. If you&#x27;re choosing between SCT0802 (Hirose DF52) and SCT0800 (JST SUR) and want to weigh signal integrity against board space, share your run length and data rate below. For hands-on evaluation, request samples of both, or send a schematic to our application engineers for a recommendation. The matching alternatives are listed in the SCONDAR wire-to-board catalog.<\/p>","protected":false},"excerpt":{"rendered":"<p>Network extension cables are a critical yet often overlooked component in structured cabling infrastructure. Whether extending a run between a router and a switch in a server rack, bridging signal connections across industrial control cabinets, or connecting peripheral network devices in a commercial building, the connector at each termination point must reliably preserve signal integrity [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-80811","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Wire-to-Board Connectors for Network Extension Cables: Selection Guide - SCONDAR<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.scondar.com\/ru\/2026\/10\/26\/wire-to-board-connectors-for-network-extension-cables-selection-guide\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Wire-to-Board Connectors for Network Extension Cables: Selection Guide - SCONDAR\" \/>\n<meta property=\"og:description\" content=\"Network extension cables are a critical yet often overlooked component in structured cabling infrastructure. Whether extending a run between a router and a switch in a server rack, bridging signal connections across industrial control cabinets, or connecting peripheral network devices in a commercial building, the connector at each termination point must reliably preserve signal integrity [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.scondar.com\/ru\/2026\/10\/26\/wire-to-board-connectors-for-network-extension-cables-selection-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"SCONDAR\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-26T05:45:01+00:00\" \/>\n<meta name=\"author\" content=\"info@scondar.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c\" \/>\n\t<meta name=\"twitter:data1\" content=\"info@scondar.com\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/26\\\/wire-to-board-connectors-for-network-extension-cables-selection-guide\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/26\\\/wire-to-board-connectors-for-network-extension-cables-selection-guide\\\/\"},\"author\":{\"name\":\"info@scondar.com\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\"},\"headline\":\"Wire-to-Board Connectors for Network Extension Cables: Selection Guide\",\"datePublished\":\"2026-10-26T05:45:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/26\\\/wire-to-board-connectors-for-network-extension-cables-selection-guide\\\/\"},\"wordCount\":1877,\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"ru-RU\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/26\\\/wire-to-board-connectors-for-network-extension-cables-selection-guide\\\/\",\"url\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/26\\\/wire-to-board-connectors-for-network-extension-cables-selection-guide\\\/\",\"name\":\"Wire-to-Board Connectors for Network Extension Cables: Selection Guide - SCONDAR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#website\"},\"datePublished\":\"2026-10-26T05:45:01+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/26\\\/wire-to-board-connectors-for-network-extension-cables-selection-guide\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/26\\\/wire-to-board-connectors-for-network-extension-cables-selection-guide\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/10\\\/26\\\/wire-to-board-connectors-for-network-extension-cables-selection-guide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.scondar.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wire-to-Board Connectors for Network Extension Cables: Selection Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#website\",\"url\":\"https:\\\/\\\/www.scondar.com\\\/\",\"name\":\"SCONDAR\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.scondar.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\",\"name\":\"info@scondar.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"caption\":\"info@scondar.com\"},\"sameAs\":[\"https:\\\/\\\/www.scondar.com\"],\"url\":\"https:\\\/\\\/www.scondar.com\\\/ru\\\/author\\\/scondar-2\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Wire-to-Board Connectors for Network Extension Cables: Selection Guide - SCONDAR","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.scondar.com\/ru\/2026\/10\/26\/wire-to-board-connectors-for-network-extension-cables-selection-guide\/","og_locale":"ru_RU","og_type":"article","og_title":"Wire-to-Board Connectors for Network Extension Cables: Selection Guide - SCONDAR","og_description":"Network extension cables are a critical yet often overlooked component in structured cabling infrastructure. Whether extending a run between a router and a switch in a server rack, bridging signal connections across industrial control cabinets, or connecting peripheral network devices in a commercial building, the connector at each termination point must reliably preserve signal integrity [&hellip;]","og_url":"https:\/\/www.scondar.com\/ru\/2026\/10\/26\/wire-to-board-connectors-for-network-extension-cables-selection-guide\/","og_site_name":"SCONDAR","article_published_time":"2026-10-26T05:45:01+00:00","author":"info@scondar.com","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c":"info@scondar.com"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.scondar.com\/2026\/10\/26\/wire-to-board-connectors-for-network-extension-cables-selection-guide\/#article","isPartOf":{"@id":"https:\/\/www.scondar.com\/2026\/10\/26\/wire-to-board-connectors-for-network-extension-cables-selection-guide\/"},"author":{"name":"info@scondar.com","@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3"},"headline":"Wire-to-Board Connectors for Network Extension Cables: Selection Guide","datePublished":"2026-10-26T05:45:01+00:00","mainEntityOfPage":{"@id":"https:\/\/www.scondar.com\/2026\/10\/26\/wire-to-board-connectors-for-network-extension-cables-selection-guide\/"},"wordCount":1877,"articleSection":["Uncategorized"],"inLanguage":"ru-RU"},{"@type":"WebPage","@id":"https:\/\/www.scondar.com\/2026\/10\/26\/wire-to-board-connectors-for-network-extension-cables-selection-guide\/","url":"https:\/\/www.scondar.com\/2026\/10\/26\/wire-to-board-connectors-for-network-extension-cables-selection-guide\/","name":"Wire-to-Board Connectors for Network Extension Cables: Selection Guide - SCONDAR","isPartOf":{"@id":"https:\/\/www.scondar.com\/#website"},"datePublished":"2026-10-26T05:45:01+00:00","author":{"@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3"},"breadcrumb":{"@id":"https:\/\/www.scondar.com\/2026\/10\/26\/wire-to-board-connectors-for-network-extension-cables-selection-guide\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.scondar.com\/2026\/10\/26\/wire-to-board-connectors-for-network-extension-cables-selection-guide\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.scondar.com\/2026\/10\/26\/wire-to-board-connectors-for-network-extension-cables-selection-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.scondar.com\/"},{"@type":"ListItem","position":2,"name":"Wire-to-Board Connectors for Network Extension Cables: Selection Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.scondar.com\/#website","url":"https:\/\/www.scondar.com\/","name":"SCONDAR","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.scondar.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Person","@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3","name":"info@scondar.com","image":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","caption":"info@scondar.com"},"sameAs":["https:\/\/www.scondar.com"],"url":"https:\/\/www.scondar.com\/ru\/author\/scondar-2\/"}]}},"_links":{"self":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/80811","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/comments?post=80811"}],"version-history":[{"count":1,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/80811\/revisions"}],"predecessor-version":[{"id":80812,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/80811\/revisions\/80812"}],"wp:attachment":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/media?parent=80811"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/categories?post=80811"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/tags?post=80811"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}