{"id":72052,"date":"2026-06-05T15:54:37","date_gmt":"2026-06-05T07:54:37","guid":{"rendered":"https:\/\/www.scondar.com\/?p=72052"},"modified":"2026-07-03T15:56:52","modified_gmt":"2026-07-03T07:56:52","slug":"industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment","status":"publish","type":"post","link":"https:\/\/www.scondar.com\/ru\/2026\/06\/05\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\/","title":{"rendered":"Industrial Ethernet Connectors: Selecting the Right Wire-to-Board Solution for Network Equipment"},"content":{"rendered":"<h2><strong><b>Application Context &amp; Design Challenge<\/b><\/strong><\/h2>\n<p>Industrial Ethernet equipment \u2014 including managed switches, routers, and gateway modules \u2014 demands interconnect solutions that balance three often-competing requirements: reliable signal integrity at PCB level, adequate current delivery for PoE (Power over Ethernet) or auxiliary power rails, and long-term durability in environments with elevated temperature and vibration. Designers evaluating connector alternatives for these applications frequently face a recurring trade-off between pitch size, current capacity, and mating security.<\/p>\n<p>In our application engineering team&#8217;s experience supporting industrial automation manufacturers, two connector categories consistently surface in network equipment design-in projects: compact 3.0mm-pitch power connectors for auxiliary supply rails, and 2.5mm\u20132.54mm-pitch signal connectors for board-level I\/O. SCONDAR&#8217;s SCT3001 series and SCT2504 series address these two distinct requirements respectively, both offering footprint-compatible alternatives to recognized brand standards at a compelling total cost of ownership.<\/p>\n<p>For industrial Ethernet switch and router applications requiring reliable PCB-level power delivery, we recommend <strong>SCONDAR SCT3001<\/strong>\u00a0as the primary interconnect solution.<\/p>\n<p>For signal-level board connections in network communication equipment, SCONDAR SCT2504 (2.5mm pitch, friction-lock) and SCT25414 (2.54mm pitch, polarized shroud) are well-suited companion products in mixed-density board designs.<\/p>\n<h2><strong><b>Technical Specification Overview<\/b><\/strong><\/h2>\n<table>\n<tbody>\n<tr>\n<td width=\"108\"><strong>Parameter<\/strong><\/td>\n<td width=\"108\"><strong>SCONDAR SCT3001<\/strong><\/td>\n<td width=\"108\"><strong>SCONDAR SCT2504<\/strong><\/td>\n<td width=\"108\"><strong>SCONDAR SCT25414<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"108\">Compatible Original<\/td>\n<td width=\"108\">Micro-Fit<\/td>\n<td width=\"108\">JAE IL-G<\/td>\n<td width=\"108\">Samtec Mini Mate<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u0430\u044f \u043f\u043b\u043e\u0449\u0430\u0434\u043a\u0430<\/td>\n<td width=\"108\">3.0 mm<\/td>\n<td width=\"108\">2,5 \u043c\u043c<\/td>\n<td width=\"108\">2.54 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a<\/td>\n<td width=\"108\">5 A AC\/DC<\/td>\n<td width=\"108\">3 A<\/td>\n<td width=\"108\">3 A<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td>\n<td width=\"108\">250 V<\/td>\n<td width=\"108\">250 V<\/td>\n<td width=\"108\">1000 V<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">Operating Temp.<\/td>\n<td width=\"108\">-40\u00b0C ~ +105\u00b0C<\/td>\n<td width=\"108\">-25\u00b0C ~ +85\u00b0C<\/td>\n<td width=\"108\">-25\u00b0C ~ +85\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">\u0421\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432<\/td>\n<td width=\"108\">10 m\u03a9 Max<\/td>\n<td width=\"108\">20 m\u03a9 Max<\/td>\n<td width=\"108\">20 m\u03a9 Max<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">Insulation Resistance<\/td>\n<td width=\"108\">1000 M\u03a9 Min<\/td>\n<td width=\"108\">1000 M\u03a9 Min<\/td>\n<td width=\"108\">1000 M\u03a9 Min<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">\u0412\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td>\n<td width=\"108\">1500 V AC\/min<\/td>\n<td width=\"108\">1000 V AC\/min<\/td>\n<td width=\"108\">1000 V AC\/min<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">No. of Circuits<\/td>\n<td width=\"108\">1\u201312; Dual-row 2\u00d71 to 2\u00d712<\/td>\n<td width=\"108\">2\u201316 positions<\/td>\n<td width=\"108\">2\u201325; Dual-row 2\u00d72 to 2\u00d725<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">Wire Range (AWG)<\/td>\n<td width=\"108\">#22 \u2013 #28<\/td>\n<td width=\"108\">#22 \u2013 #28<\/td>\n<td width=\"108\">#20 \u2013 #24<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">\u0421\u0442\u0438\u043b\u044c \u0437\u0430\u0434\u0435\u043b\u043a\u0438<\/td>\n<td width=\"108\">Crimp<\/td>\n<td width=\"108\">Crimp<\/td>\n<td width=\"108\">Crimp<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">\u041c\u0435\u0445\u0430\u043d\u0438\u0437\u043c \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438<\/td>\n<td width=\"108\">Friction Lock<\/td>\n<td width=\"108\">Friction Lock<\/td>\n<td width=\"108\">Metal or Plastic Latch<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">Keying \/ Polarization<\/td>\n<td width=\"108\">Anti-misinsertion design<\/td>\n<td width=\"108\">Anti-misinsertion key<\/td>\n<td width=\"108\">Polarized &amp; Keyed shroud<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">Housing Material<\/td>\n<td width=\"108\">PA66 UL94V-0 (Halogen-free)<\/td>\n<td width=\"108\">PA66 UL94V-0<\/td>\n<td width=\"108\">PA66 UL94V-0<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">Terminal Material<\/td>\n<td width=\"108\">Phosphor Bronze, Gold\/Tin plating<\/td>\n<td width=\"108\">Phosphor Bronze, Tin plating<\/td>\n<td width=\"108\">Phosphor Bronze, Tin plating<\/td>\n<\/tr>\n<tr>\n<td width=\"108\">\u0421\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b<\/td>\n<td width=\"108\">ISO 9001:2015 \/ RoHS \/ REACH<\/td>\n<td width=\"108\">ISO 9001:2015 \/ RoHS \/ REACH<\/td>\n<td width=\"108\">ISO 9001:2015 \/ RoHS \/ REACH<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2><strong><b>Design-In Considerations: Mechanical &amp; Process<\/b><\/strong><\/h2>\n<h3><strong><b>Pitch-to-AWG Matching for Network Equipment Boards<\/b><\/strong><\/h3>\n<p>A common oversight in network hardware design is mismatching connector pitch with wire gauge. The SCT3001&#8217;s 3.0mm pitch supports AWG #22\u2013#28, accommodating both heavier-gauge power wires (for 5A supply rails) and finer signal wires. This flexibility simplifies cable harness routing in compact switch enclosures where multiple power and signal circuits share limited cross-section. For the SCT2504 at 2.5mm pitch, the same AWG range applies, but designers should verify that crimp height settings on automated termination equipment are adjusted specifically for the 2.5mm pitch housing to maintain consistent pull-out force across production runs.<\/p>\n<h3><strong><b>Crimp Termination Quality Assurance<\/b><\/strong><\/h3>\n<p>Both the SCT3001 and SCT2504 use a crimp-style termination. In our manufacturing validation lab, crimp height and pull-out force are monitored on every batch using calibrated tensile testing equipment. For network equipment manufacturers, we recommend the following process checkpoints:<\/p>\n<ul>\n<li>Crimp height tolerance: \u00b10.03 mm (measured with optical micrometer)<\/li>\n<li>Pull-out force: \u2265 20 N for AWG #22; \u2265 10 N for AWG #28 (consistent across 100-cycle endurance sample)<\/li>\n<li>Visual inspection: barrel closed without flash; conductor visible in inspection window<\/li>\n<li>Contact resistance: \u2264 10 m\u03a9 (SCT3001) and \u2264 20 m\u03a9 (SCT2504) at mated condition<\/li>\n<\/ul>\n<h3><strong><b>Wide-Temperature Performance for Outdoor Network Nodes<\/b><\/strong><\/h3>\n<p>Industrial Ethernet switches deployed in outdoor cabinets or unconditioned enclosures must operate across a wide temperature swing. The SCT3001&#8217;s -40\u00b0C to +105\u00b0C operating range directly addresses this requirement. The connector&#8217;s isolated terminal design provides grounding protection \u2014 a relevant feature in electrically noisy industrial network environments where electromagnetic interference (EMI) from adjacent power conductors can degrade signal integrity in unshielded twisted-pair Ethernet links.<\/p>\n<h3><strong><b>Board Space Optimization in High-Port-Count Switches<\/b><\/strong><\/h3>\n<p>Modern managed switches with 24 or 48 ports require high-density board layouts. The SCT3001 is available in dual-row configurations up to 2\u00d712 circuits, allowing engineers to consolidate multiple power rails into a single connector footprint. The SCT25414 extends this flexibility with circuit counts up to 50 positions in a single- or dual-row format, supporting multi-port signal bus connections in board-to-cable configurations. Both series feature polarizing keys and shrouded headers to prevent mis-mating during field service \u2014 a practical consideration when servicing network equipment in rack installations.<\/p>\n<h2><strong><b>Quality Assurance &amp; Supply Chain<\/b><\/strong><\/h2>\n<ul>\n<li>ISO 9001:2015 certified manufacturing (Certificate No. 02816Q11592RS) with 80% automated production capacity<\/li>\n<li>UL\/cUL certified (E538921) and SGS-tested for RoHS and REACH compliance \u2014 full test reports available on request<\/li>\n<li>Automated crimp-height monitoring and 100% continuity testing on all wire-to-board assemblies<\/li>\n<li>Sample orders accepted; free tooling samples available for design-in validation<\/li>\n<li>On-time delivery rate: 98.4%; standard lead time: 1\u20133 weeks for in-stock items<\/li>\n<li>200+ circuit sizes and configurations; custom harness design and assembly services available<\/li>\n<\/ul>\n<p>We have successfully delivered interconnect solutions to over 2,000+ global electronics and industrial equipment manufacturers since 2008.<\/p>\n<h2><strong><b>Frequently Asked Questions<\/b><\/strong><\/h2>\n<h3><strong><b>Q1: How do I verify that SCONDAR SCT3001 is footprint-compatible with my existing Micro-Fit PCB layout?<\/b><\/strong><\/h3>\n<p>SCONDAR SCT3001 follows the Micro-Fit (3.0mm pitch) PCB footprint standard. To validate footprint compatibility, compare the header pin pattern, pitch dimension, and board-keepout zone against your existing layout. The connector is available with both SMT and through-hole headers; ensure the termination style matches your board technology. Our application team can supply sample headers and 3D STEP files upon request to verify fitment before committing to production volumes.<\/p>\n<h3><strong><b>Q2: What long-term reliability data is available for these connectors in industrial network environments?<\/b><\/strong><\/h3>\n<p>The SCT3001 is rated for 5A at 250V AC\/DC and operates from -40\u00b0C to +105\u00b0C, covering the typical ambient temperature range in enclosed industrial Ethernet cabinets. The connector housing uses PA66 UL94V-0 halogen-free material, providing self-extinguishing performance in fault conditions. Accelerated thermal cycling tests (500 cycles, -40\u00b0C\/+105\u00b0C) and salt mist exposure tests are part of our internal qualification protocol; detailed test reports are available through our sales team. For PoE-plus (30W) applications at 48V DC, the SCT3001&#8217;s 250V rating provides a 5\u00d7 safety margin.<\/p>\n<p><a href=\"https:\/\/www.scondar.com\/ru\/%d0%bf%d1%80%d0%be%d0%b2%d0%be%d0%b4-%d0%ba-%d0%bf%d0%bb%d0%b0%d1%82%d0%b5\/\">Browse all SCONDAR wire-to-board connector solutions<\/a><\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Application Context &amp; Design Challenge Industrial Ethernet equipment \u2014 including managed switches, routers, and gateway modules \u2014 demands interconnect solutions that balance three often-competing requirements: reliable signal integrity at PCB level, adequate current delivery for PoE (Power over Ethernet) or auxiliary power rails, and long-term durability in environments with elevated temperature and vibration. Designers evaluating [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-72052","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Industrial Ethernet Connectors: Selecting the Right Wire-to-Board Solution for Network Equipment - SCONDAR<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.scondar.com\/ru\/2026\/06\/05\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Industrial Ethernet Connectors: Selecting the Right Wire-to-Board Solution for Network Equipment - SCONDAR\" \/>\n<meta property=\"og:description\" content=\"Application Context &amp; Design Challenge Industrial Ethernet equipment \u2014 including managed switches, routers, and gateway modules \u2014 demands interconnect solutions that balance three often-competing requirements: reliable signal integrity at PCB level, adequate current delivery for PoE (Power over Ethernet) or auxiliary power rails, and long-term durability in environments with elevated temperature and vibration. Designers evaluating [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.scondar.com\/ru\/2026\/06\/05\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\/\" \/>\n<meta property=\"og:site_name\" content=\"SCONDAR\" \/>\n<meta property=\"article:published_time\" content=\"2026-06-05T07:54:37+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-03T07:56:52+00:00\" \/>\n<meta name=\"author\" content=\"info@scondar.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c\" \/>\n\t<meta name=\"twitter:data1\" content=\"info@scondar.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 \u043c\u0438\u043d\u0443\u0442\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/06\\\/05\\\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/06\\\/05\\\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\\\/\"},\"author\":{\"name\":\"info@scondar.com\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\"},\"headline\":\"Industrial Ethernet Connectors: Selecting the Right Wire-to-Board Solution for Network Equipment\",\"datePublished\":\"2026-06-05T07:54:37+00:00\",\"dateModified\":\"2026-07-03T07:56:52+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/06\\\/05\\\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\\\/\"},\"wordCount\":973,\"commentCount\":0,\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.scondar.com\\\/2026\\\/06\\\/05\\\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/06\\\/05\\\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\\\/\",\"url\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/06\\\/05\\\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\\\/\",\"name\":\"Industrial Ethernet Connectors: Selecting the Right Wire-to-Board Solution for Network Equipment - SCONDAR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#website\"},\"datePublished\":\"2026-06-05T07:54:37+00:00\",\"dateModified\":\"2026-07-03T07:56:52+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/06\\\/05\\\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.scondar.com\\\/2026\\\/06\\\/05\\\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/2026\\\/06\\\/05\\\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.scondar.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Industrial Ethernet Connectors: Selecting the Right Wire-to-Board Solution for Network Equipment\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#website\",\"url\":\"https:\\\/\\\/www.scondar.com\\\/\",\"name\":\"SCONDAR\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.scondar.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.scondar.com\\\/#\\\/schema\\\/person\\\/5bdf51dcf11158ed6335d131d9eab9d3\",\"name\":\"info@scondar.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g\",\"caption\":\"info@scondar.com\"},\"sameAs\":[\"https:\\\/\\\/www.scondar.com\"],\"url\":\"https:\\\/\\\/www.scondar.com\\\/ru\\\/author\\\/scondar-2\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Industrial Ethernet Connectors: Selecting the Right Wire-to-Board Solution for Network Equipment - SCONDAR","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.scondar.com\/ru\/2026\/06\/05\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\/","og_locale":"ru_RU","og_type":"article","og_title":"Industrial Ethernet Connectors: Selecting the Right Wire-to-Board Solution for Network Equipment - SCONDAR","og_description":"Application Context &amp; Design Challenge Industrial Ethernet equipment \u2014 including managed switches, routers, and gateway modules \u2014 demands interconnect solutions that balance three often-competing requirements: reliable signal integrity at PCB level, adequate current delivery for PoE (Power over Ethernet) or auxiliary power rails, and long-term durability in environments with elevated temperature and vibration. Designers evaluating [&hellip;]","og_url":"https:\/\/www.scondar.com\/ru\/2026\/06\/05\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\/","og_site_name":"SCONDAR","article_published_time":"2026-06-05T07:54:37+00:00","article_modified_time":"2026-07-03T07:56:52+00:00","author":"info@scondar.com","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c":"info@scondar.com","\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f":"5 \u043c\u0438\u043d\u0443\u0442"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.scondar.com\/2026\/06\/05\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\/#article","isPartOf":{"@id":"https:\/\/www.scondar.com\/2026\/06\/05\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\/"},"author":{"name":"info@scondar.com","@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3"},"headline":"Industrial Ethernet Connectors: Selecting the Right Wire-to-Board Solution for Network Equipment","datePublished":"2026-06-05T07:54:37+00:00","dateModified":"2026-07-03T07:56:52+00:00","mainEntityOfPage":{"@id":"https:\/\/www.scondar.com\/2026\/06\/05\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\/"},"wordCount":973,"commentCount":0,"articleSection":["Uncategorized"],"inLanguage":"ru-RU","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.scondar.com\/2026\/06\/05\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.scondar.com\/2026\/06\/05\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\/","url":"https:\/\/www.scondar.com\/2026\/06\/05\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\/","name":"Industrial Ethernet Connectors: Selecting the Right Wire-to-Board Solution for Network Equipment - SCONDAR","isPartOf":{"@id":"https:\/\/www.scondar.com\/#website"},"datePublished":"2026-06-05T07:54:37+00:00","dateModified":"2026-07-03T07:56:52+00:00","author":{"@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3"},"breadcrumb":{"@id":"https:\/\/www.scondar.com\/2026\/06\/05\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.scondar.com\/2026\/06\/05\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.scondar.com\/2026\/06\/05\/industrial-ethernet-connectors-selecting-the-right-wire-to-board-solution-for-network-equipment\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.scondar.com\/"},{"@type":"ListItem","position":2,"name":"Industrial Ethernet Connectors: Selecting the Right Wire-to-Board Solution for Network Equipment"}]},{"@type":"WebSite","@id":"https:\/\/www.scondar.com\/#website","url":"https:\/\/www.scondar.com\/","name":"SCONDAR","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.scondar.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Person","@id":"https:\/\/www.scondar.com\/#\/schema\/person\/5bdf51dcf11158ed6335d131d9eab9d3","name":"info@scondar.com","image":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/0d02c747c33c0b4784c58c9ca75c2de60c4223ffa72423b59f8872ce23079a38?s=96&d=mm&r=g","caption":"info@scondar.com"},"sameAs":["https:\/\/www.scondar.com"],"url":"https:\/\/www.scondar.com\/ru\/author\/scondar-2\/"}]}},"_links":{"self":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/72052","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/comments?post=72052"}],"version-history":[{"count":1,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/72052\/revisions"}],"predecessor-version":[{"id":72053,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/posts\/72052\/revisions\/72053"}],"wp:attachment":[{"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/media?parent=72052"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/categories?post=72052"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.scondar.com\/ru\/wp-json\/wp\/v2\/tags?post=72052"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}